S’ouvre dans un nouvel onglet

FTD10000

  • 7 GHz bandwidth with slow roll off

    7 GHz bandwidth with slow roll off giving a very good impulse response

  • 2000 V maximum input voltage without overload

    It features unique performances such as a maximum input voltage of 2000 Volts without overload

  • Controlled via front panel and Ethernet

    Additional features include an input for timing fiducials and a large front panel display for easy and precise viewing.

Request a quote

Applications

  • Diagnostics for Laser research and HighEnergy physics
  • Recording of fast single shot pulses
  • EMC/EMP simulators
  • High-voltage breakdowns
  • Test of high speed circuits
  • Automatic Test Equipment (ATE)
FTD10000

Greenfield Technology’s FTD10000 7 GHz Fast Transient Digitizer is the industry’s fastest digitizer specifically designed to record very fast single shot pulses down to 50ps with 13-bit amplitude resolution.

It feature unique performances such as 7GHz bandwidth with slow roll off giving a very good impulse response, maximum input voltage of 2000 Volts without overload  and low noise giving a FS/N ratio > 3000 (  >70 dB).

The new revision adds new features and improve performance of the instrument. The new revision includes:

  • Improved readout camera with 1800 x 1800 pixels, 12-bit A/D and cooling system
  • Improved digitizing resolution by 78%
  • A “Very High” precision waveform processing
  • An internal web server to control the instrument and analyse the sampling results via a standard web-browser
  • Extended Ethernet speed up to 1000 Mb/s

Additional features include an input for timing fiducials and a large front panel display for easy and precise viewing.

An interface GUI allows local and remote control of all setup and digitizing features and viewing of results.

As such the FTD10000 is an excellent solution for the following applications:

  • Diagnostics for Laser research and High-Energy physics
  • Recording of fast single shot pulses
  • EMC/EMP simulators
  • High-voltage breakdowns
  • Test of high speed circuits
  • Automatic Test Equipment (ATE)

The FTD1000 is a licensed product developped under CEA (Comissariat à l’Energie Atomique) contract.

Key features

  • Number1

Signal Input

  • Sensitivity4.5 V into 50 Ω must be externally terminated
  • BandwidthDC to 7 GHz (4 dB)
  • Rise time50 ps
  • Input impedance50 Ω
  • Vertical position +50 % to –50 %
  • Maximum input 2000 V (at FWHM = 1 µs)

External Trigger

  • Input impedance50 Ω (internal)
  • Signal polarity Positive or negative
  • Signal duration>0.5 ns
  • Trigger level0.5 V to 4 V
  • Maximum input500 V (at FWHM = 1 µs)
  • Internal delay40 + (10-¹ X analysis duration) to 540 ns

Soft Trigger

  • Trigger SourceEthernet/ Internet command

Trigger output

  • FunctionMark beginning of sweep
  • Level / rise time10 V / 5 ns into 50 Ω
  • ShapeImpulse wave, with FWHM >100 ns

Digitizing

  • Analysis sweep duration (ns) : Sampling rate (GS/s)
    1 : 1800
    2 : 900
    5 : 360
    10 : 180
    20 : 90
    50 : 36
    100 : 18
    2000 : 0.9
  • Horizontal resolution 1800 samples
  • Non-volatile memory1 record & settings
  • Full Scale /Noise Ratio3000 (70 dB) at 10 ns Analysis sweep duration
  • Acquisition modeSingle acquisition or repetitive acquisitions at max rate of 0,7 Hz (TBC) or electrical zero
  • Waveform processingRaw data (image), Fast (waveform), High (corrected waveform), Very High precision (corrected waveform) with PC software application.

System control

  • Command and SettingVia Ethernet and Internet (Web pages)
  • Data transferVia Ethernet (10/100/1000 Mb/s)
  • LEDsFor viewing instrument status
  • Local viewing and controlWith 8”2 LCD display, keyboard and knob
  • SoftwareLabView application for Windows 10

Fiducial input

  • FunctionSMA connector provides a marker synchronous of recorded signal. The fiducial input signal is added to the signal input.
  • Sensitivity0 to 3 V amplitude adds 10% of FS
  • Bandwidth0.1 MHz to 3 GHz
  • Impedance40 Ω

Main Characteristics (cont’d)

Inputs /outputs (all are located at rear of the equipment)

  • Signal input and outputN connectors
  • Trigger inputBNC connector
  • Trigger outputBNC connector
  • Fiducial inputSMA connector
  • Ethernet port RJ-45

Environment

  • Operating temperature10 to 30°C
  • Humidity85% non-condensed at 40°C

Power supply

  • Voltage90 to 240 VAC
  • Power consumption100 W

Physical characteristics

  • Dimensions
    Width =19 inch
    Height = 173 mm (4 U)
    Depth = 560 mm (670 mm with handles)
  • Weight20 kg
  • Download data sheet

    Lorem ipsum dolor sit amet, consectetur adipiscing viverra ornare, eros dolor nulla.
    Download file
  • Lorem ipsum

    Lorem ipsum dolor sit amet, consectetur adipiscing viverra ornare, eros dolor nulla.
    Learn more